TriggerFoam Pro is a one part polyurethane expanding foam, designed to effectively block the spread of smoke and flame in Type V residential construction. Triggerfoam Pro sets into its final form by using moisture present in the air. When installing the foam, consideration should be given to the 2-3 times expansion of the foam after it leaves the nozzle. The surface of the foam initially dries within 1-5 hours and becomes fully cured in 12-15 hours. TriggerFoam Pro sets well on ordinary surfaces such as concrete, brick, metal, etc. Surfaces do not require preparation and can also be damp. After installation, it is recommended that a full 24 hours elapse prior to scraping, sanding, staining or painting. The foam has a R-5 equivalent value when used in place of traditional installation methods. TriggerFoam Pro is dispensed through a special gun that allows the user to control the rate of flow as well as the size of the bead for more precise placement of the product, allowing it to be used in a wide variety of applications. Use it to fill, seal or insulate. It blocks drafts, stops leaks, saves energy, adheres to all types of construction materials, deadens sound, acts as a buoyancy material once cured, controls radon, helps confine asbestos fibers, and can be used in HVAC applications.
Features
- CFC free propellant
- Class B2 Flame retardant
- Physiologically harmless when fully cured
- Contains no urea formaldehyde or PCB's
- Does not rot or deteriorate with age
- Low odor
- High foam yield – up to 1.8 ft3 per 29 oz. can
- Easily adjustable applicator can dispense foam beads as small as 1/8"
- Hardened steel dispenser tip for longer life on metal tools
- Precision valve helps prevent pressure loss and prolongs shelf life
- Stop and go application, product remains liquid in applicator until dispensed
- Minimal subsequent expansion (±10%)
- Compatible with PVC
- VOC: 185.5 g/L
General Application & Uses
Insulating
- Around window frames, sills, door frames floor/wall joints
- Refrigeration units and pipes
- Electrical junction boxes
- Attics
- Air conditioning systems
Filling
- Breaches in walls
- Sound Dampening
- Voids in concrete forms
- Pipe penetrations in non-fire rated walls
- Underground ductwork
- Gaps in construction materials
Approvals
- International Code Council Evaluation Service (ICC-ES), ESR-3263 for Thermal and Moisture Protection and annular space protection for wood fire blocking. Code compliant with the 2021 IBC/IRC, 2018 IBC/IRC, 2015 IBC/IRC, and 2012 IBC/IRC.
- Underwriters Laboratory (UL Listing) – File No. R16754, Caulkings and Sealants Tested in accordance with UL 723 “Test for Surface Burning Characteristics of Building Materials” and ASTM E814M Applied to Inorganic Reinforced Cement Board tested as applied in two 3/4" diameter beads, 5" OC covering 12.5 percent of the exposed test area: Flame spread 5 Smoke developed 10
- Tested in accordance with ASTM E90 (Sound Transmission Classification 60), ASTM C518 and ASTM C423